Interchim PuriFlash Flash Chromatography Purification System PF-5.007

$31999.00

Purify large quantities of raw materials

Do you need to purify several hundred grams of the compounds of interest in a single run? If you want to do this with complete confidence and unparalleled results, then a puriFlash® device is all you need.
With its 750 ml/min and its column support with which Flash columns can be adapted up to format F1600, you will receive a maximum amount of products and your purification yield will always be optimal.

Its long-lasting reliability and robustness, as well as its safety features are key benefits to carrying out your productions semi-continously and with volumes of up to several hundred grams of the compounds of interest.
With the puriFlash® 5.007, you benefit from production continuity on the same device, regardless of the scale-up factor.

Components

  • Control unit

  • Pump

  • UV detector

  • Fraction collector

  • Solvent tray with drainage system

  • Integrated column holder

  • Integrated Dry-Load holder

Pump

  • Flow rate range: 10 mL/min to 825 mL/min

  • Max. operational flow rate: 825 mL/min

  • Optimum flow rate for columns up to F3000 format

  • Flow rate accuracy: +/- 2 % over 100 to 750 mL/min & 5 to 12 bar

  • Flow rate repeatability: < 0.25

  • Flow rate linearity: 0.98 < linearity < 1

  • Pressure range: 0 to 15 bar

  • Max. operational pressure: 15 bar

  • Quaternary gradient valve

  • Gradient tolerance step: < 3.5 %

  • Washing disks

Injection

  • Injection mode: liquid or solid

  • RFID technology: automatic detection of the Dry-Load

Detection

  • UV detector 200-400 nm

  • UV detector 200-800 nm

  • ”DAD” technology

  • Multi-wavelength and scan collection over a band of 200 nm

  • Spectral visualization and confirmation of purity

  • Flow cell pathway: 0.3 mm / 80 µL

Column & support compatibility

  • Normal phase(NP)
    Particle sizes: 15 µm, 25 μm, 30 μm, 40 μm , 50 μm

  • Reverse phase (RP)
    Particle sizes: 30 µm, 50 µm

  • Format: all Flash columns up to F1600 format & Dry-Load up to F0330 format are compatible

  • Integrated column holder

  • Integrated Dry-Load holder

  • RFID technology: automatic detection of the columns

Fraction collector

  • Capacity:
     3 racks
     42 test tubes (29,5 x 200 mm)

  • Technology:
     Automatic cleaning of the fraction collector needle (to avoid cross-contamination with the previous purification)
     RFID: automatic detection of the racks installed in the fraction collector